| TRANSPORT MULTIPARA MONITOR |
| Standard
Features:- |
|
| Þ |
10.4" Colour TFT, 5 Channel Monitor. |
|
| Þ |
ST segment (dot) automatic analysis and ECG wave freezing with manual analysis. |
| Þ |
Graphical & tabular trends for upto 12 / 24 / 96 hours with zoom facility. |
| Þ |
Simultaneous viewing of trends with current data. |
| Þ |
Memory and view a list of up to 400 groups of parameter data. |
| Þ |
ECG waveform can be stored for 24 hours. |
| Þ |
Resistance against interference from defibrillator, electrical cautery. It can be used along with cardiac pacemaker. |
| Þ |
Adult / infant / neonate modes. |
| Þ |
12VDC external supply input for transport. |
| |
| ECG (5 Lead) |
| Range of heart rate |
: |
0-300 bpm. |
| Accuracy of HR |
: |
± 2%. |
| Frequency response |
: |
0.05
- 100Hz. |
| Optional ECG lead |
: |
I, II, III, avR, avL, avF,
V1-V6, GND. |
| Measurement of ST segment |
: |
-2.0-2.0 mV, (Auto). |
| VPC analysis |
: |
Provided. |
| Lead off |
: |
Audio & visual alarms. |
| Scan speed |
: |
12.5, 25 , 50mm/sec. |
| Protection |
: |
Isolation breakdown voltage 4000VAC, 50/60HZ against high-frequency electrocautery, myoelectricity, AC, drifting interference. |
| Bandwidth |
: |
0.5 - 40Hz (Monitor mode)
0.05 - 100Hz (Diagnostic mode)
1 - 15Hz (Surgical mode) |
| Alarm range |
: |
High / Low limit setting, auto memory. |
|
| |
|
| |
| Temperature |
| Range of TEMP |
: |
15-45° C. |
| Accuracy of TEMP |
: |
± 0.2° C. |
| Sensors |
: |
Reusable sensor for body skin or rectum. |
| Alarm range |
: |
Optional High / low limit, auto-memory. |
|
| |
|
| |
| Respiration |
| Measurement method |
: |
Chest impedance. |
| Range of RR |
: |
0-120 bpm. |
| Accuracy of RR |
: |
± 2 bpm. |
| Alarm range |
: |
High / low limit, auto-memory. |
|
| |
|
| |
| Configuration |
| Standard |
: |
Heart Rate, Blood Pressure, Pulse Oximetry, Respiration, Temperature, Pulse, Built-in Battery. |
| Optional |
: |
External Printer, Dual Invasive Blood Pressure or
EtCO |
|
| |
|
| |
| Display |
| 10.4" TFT, 5 Channel Colour display. |
|
| |
|
| |
| Non - invasive blood pressure |
| |
| Measurement method |
: |
Oscillometric. |
| Measured parameters |
: |
Systolic, diastolic, mean, pulse. |
| Working mode |
: |
Manu, auto, 5 minutes STAT. |
| Range of measurement |
: |
Adult 10-135 mmHg.
Infant 10-200 mmHg.
Neonate 10-135 mmHg. |
| Pressure of CUFF |
: |
0-320 mmHg. |
| Unit |
: |
mmHg or Kpa. |
| Type of CUFF |
: |
Adult, infant or neonate. |
| Cuff inflation |
: |
< 10 sec. |
| Cuff deflation |
: |
< 20 sec. |
| Alarm range |
: |
High / Low limit, auto-memory. |
|
| |
| |
| Pulse oximetry |
| Measured parameter |
: |
SpO pulse bar graph, waveform, pulse rate. |
| Range of Sp0 |
: |
0-100% adult / infant / neonate. |
| Accuracy of Sp0 |
: |
± 1% (70%-100%).
± 2% (50%-69%).
|
| Range of pulse |
: |
0-255 bpm. |
| Accuracy of pulse |
: |
± 2 bpm. |
| Sensor |
: |
Adult finger or infant multi-site Y - type or neonatalwrap sensor. |
| Alarm range |
: |
High / Low limit, auto-memory. |
|
| |
|
| |
| General |
| |
| Printer type |
: |
Thermal matrix recorder or standard printer |
| Printer style |
: |
Records waves, text and graphs. |
| Power |
: |
165-265 VAC/47- 63 Hz or 12VDC External supply.
|
| Power Consumption |
: |
About 35 W. |
| Gross weight |
: |
6.5 Kg. |
| PC-5000 size |
: |
260 H X 290 W X 140 D (mm). |
| Battery |
: |
Lead acid, built in rechargeable. |
| Use time after recharge |
: |
2 hours. |
Trend time
|
: |
1 - 96 hours. |
| Safety standard |
: |
IEC 601-1 (international GB9706. 1). |
|
| |
Most of our product provides you
with the excellent quality of paediatric equipments like multipara monitor system , central monitor system. We need to
work with our customers to understand their needs. We
are also supplier of other important
products like Laryngoscopes, Surgical disposable,
Vaccine carrier, Orthopaedic implants etc.
We are selling our products in Asia,
United Kingdom, Jordan,
Japan, Saudi Arabia and Philippines.
|