Home Home      Site Map Site  Map     Enquiry Enquiry
Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales
 
Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales
Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales
Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales
Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales
Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales
Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales
 
Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales Anaesthesia equipment,laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier,Weighing scales
E-mail : sales@ademcoindia.com    
- OUR PRODUCTS -
Anaesthesia Equipment & Products
Baby Care/Paediatric Equipments
Cold Chain Equipment
Diagnostic Equipments
Monitoring Equipments
Hospital/Medical Furniture
Laryngoscopes
Miniature Lamps
Microscopes
Orthopaedic Instrument & Implants
Operation Theater Lights
Pulse Oximeter
Scientific & Laboratory Equipments
Stethoscopes
Surgical Disposables
Suction Units
Wheel Chairs
Weighing Scales
Diagnostic Equipment & Products
Dental Instruments
OB GYN (Gynecological) Products
Autoclaves
Shadowless Lights
Emergency Medical Products & Supplies
General Surgery Instruments
Disposable/Surgical Medical Products
Medical Instrument Disposable
Hospital Garments
Rehabilitation Aids
Surgical Medical & Rubber Goods
Stainless Steel Hospital Holloware and Sterilizers
Miscellaneous Surgical/Medical Products
Surgical Needles
Suction Machines & Units
Hospital Holloware
Microscopes and Projectors
#
About Us Products Contact Us Product Category
Laryngoscope,Microscopes,Miniature lamps,Miniature bulb,suction unit,Stethoscopes,vaccine carrier
 
Other Monitoring equipment in this Category:
»
VENTILATOR : PM-016(a)
  Standard Features:-
  Key Benefits
  Adaptive Bi-Level™
Þ
With its Adaptive Bi-Level capabilities, VersaMed is the first manufacturer to address the need for a functional, reliable and comfortable leak tolerant ventilator specifically designed for face mask, tracheostomy and cuff-less endotrachael tube ventilation.
Þ
Adaptive Bi-Level works with a combination of two standard modes of ventilation - a pressure control mode of ventilation, where the end expiratory pressure and inspiratory pressure are specified along with the breath rate (patients can also initiate a breath) and I:E ratio combined with the feature of pressure support ventilation whereby breath termination can be controlled by the patient.
Þ
This type of ventilation operates in a leak tolerant mode. This means that the ventilator will provide patient disconnect alarms and PIP and PEEP alarms that are aware of the constant leak associated with face-mask ventilation.
  Adaptive Flow™
Þ Adaptive Flow allows the patient to receive the amount of flow they desire. Adaptive Flow performs 3 functions:
Þ
For a non-breathing patient, Adaptive Flow will utilize the lowest possible peak flow to deliver a breath in the allotted inspiratory time. By delivering the breath at the lowest peak flow the inspiratory pressures for that breath are minimized thus reducing the risk of barotrauma.
Þ
For a spontaneously breathing patient, Adaptive Flow detects and matches the patient ‘s natural inspiratory flow rate.
Þ
For timed breaths interspersed with spontaneous breaths adaptive flow delivers the appropriate flow necessary to reach the target volume within the allotted time, while maintaining an I-time that results in an I:E of 1:2.
  Adaptive I-Time™
Þ
This feature, which can be activated in volume mode, allows the patient to take charge of their inspiratory time while keeping their I:E ratio at 1:2. In this mode, if the patient's rate increases, the ventilator decreases I-Time in an attempt to keep the 1:2 ratio and conversely will increase the I-Time if the rate drops.
Þ
The Rise Time is automatic and Adaptive I-Time is generally used in unison with Adaptive Flow. When combined the two features dramatically increase patient comfort by
Þ Reducing Air Hunger
Þ Decreasing Dyspnea
Þ Reducing PIP
  Pressure Limited Volume Ventilation
Þ
The iVent201 has the capability to limit the delivery pressure of a volume breath. This feature allows the user to set a pressure limit, the pressure a breath will not exceed. This ensures the pressures will remain low enough to protect the lung from barotrauma. If the target pressure is reached during the inspiratory phase, the ventilator will “hold” the breath at the set pressure until the I-Time is reached.
  Quick set-up
Þ The iVent201 has pre-determined settings based on the patients' ideal body weight. This allows very quick application of the vent in emergency/non-clinician settings.
  Sound Investment
Þ
Healthcare providers can use one machine (and one circuit) for a broad range of patients from pediatric to adult with invasive and face mask ventilation and CPAP,
Þ
A portable ventilator with the advanced capabilities of a heavy-duty ventilator, the iVent201 is ideal in the ER, ICU, transport, EMS, long-term care/sub-acute, and home care.
  Apnea Backup Ventilation
Þ
In case of apnea, the iVent201 will initiate ventilation based on an average of the previous twelve breaths. If apnea is detected prior to an average taken, the ventilator will use the IBW, which was set at start up.
Þ For instance, if the patient was in a volume mode, the patient will receive a Vt of 10 ml per selected kg, and the rate will vary based on the weight chosen.
  Internal PEEP
Þ
The iVent201 utilizes a mushroom valve located in the expiratory limb of the circuit to control exhalation and PEEP. A sensor line applies and maintains the clinician set pressure on the valve. This system is much more accurate and adds considerably less weight than the dial type valves located at the distal end of some ventilator circuits.
  Easy Exhale
Þ
Easy Exhale is a patient comfort feature found on the iVent201. This feature unloads all resistance from the expiratory valve at the beginning of exhalation. Once the baseline PEEP has been met, the PEEP is then reapplied. By exhaling against zero PEEP, the patient's expiratory work of breathing is greatly reduced and comfort dramatically increased.
  Software Upgradeability
Þ
The iVent201 is based on computer platform that allows it to be upgraded in the same manner as the software on a PC. Many other software driven ventilators utilize EPROM programs that are not upgradeable, and updates mean a complete program change out is needed.
Þ With the iVent201 we just add on to existing software program which makes the upgrade fast, easy and able to be performed on site with very little down time.
  Ease of Use
Þ
The menu on the iVent201 is accessed by the click-turn-click rotational control that makes it very user friendly. The user is never more than one menu deep in the program. Most functions operate from a popup screen format.
  Critical Care Vent in a Compact Package
Þ
The iVent201 has the ventilation modalities and capacity to handle 90% of all patients requiring ventilation. It is the first ventilator on the market designed to handle both face mask and invasive.
  Transportable Face-Mask Ventilation
Þ
Weighing 22lbs, the iVent201 with its self-contained turbine and internal battery is the only truly transportable ventilators capable of providing face mask ventilation.
 
Physical Features

User Interface

Single Rotational control, push/turn to access all data and menu information Color LCD that indicates all settings and actual parameters. Graphics and special menu functions are also presented for clinician use Clinician chosen display interface: ICU/Monitoring/Home Care

Physical Design

Designed for easy cleaning and quick turn-around Rugged build Small, lightweight design allows for easy transport

   
 
Configuration Features

Quick set-up

The iVent201 has pre-determined settings based on the patients' ideal body weight. This allows very quick application of the vent in emergency/non-clinician settings

Circuit Compliance

Not necessary as all pressures, volumes and compensation flows are measured at the patients' wye

Pre-set Default

Used for typical setting for specific clinical applications

Patient Triggers

Configured to have both pressure and flow triggers as default. First trigger sensed initiates breath

   
 
Modes:

Assist Control, Volume Assist Control, Pressure SIMV, Volume SIMV, Pressure CPAP/PSV Pressure Limited Volume Control Pressure Limited Volume Control

All modes of ventilation may be used with both pediatric and adult patients. This allows great versatility to meet clinical demands

   
 
Manual Controls:

Alarm Silence

Mutes the alarm for two minutes

100% O2

Pressing this key allows for 3 minutes of 100% O2 and two minutes of alarm silence during suction procedures

Manual Breath

Enables the operator to deliver a single breath. In the CPAP/PSV modes, where there isn't any defined machine breath, the delivered breath will be default volume for the specified patient weight

Clear

This key will minimize alarm pop-ups and mute the alarm for 30 seconds. This key also aborts the last operator action and returns to the previous position. When held for 2 seconds, all corrected alarm messages (displayed in green) are cleared from the screen and/or alarm silence is cancelled

   
 
Trends/Log Book

Patient Trends

There are 14 different parameters available to trend. Trended information is held for 72 hours on a first in, first out basis. This information can be browsed with a cursor for exact information at exact times.

Log Book

Parameter changes and alarms are logged for 300 events on

 

a first in, first out basis. The viewable log is erased once the unit is powered off.

   
 
Proximal Flow/Pressure/Volume Sensing

Dual Pressure Transducers

The combination of proximal and distal pressure sensors in the circuit wye allows for extremely accurate measurements of delivered and exhaled volumes. The iVent computer deciphers pressure changes into volume and flow.

   
 
Advanced Mechanics

Compliance

Updated breath to breath

Mean Airway Pressure

Updated breath to breath

Airway Resistance

Updated breath to breath

   
 
Monitored Parameters
 

Mandatory Vt

 

Set PEEP

 

Updated breath to breath

 

Actual Vt

 

PIP with bar graph

 

% Leak

 

MAP

 

Mandatory RR

 

Resistance

 

Actual RR

 

Compliance

 

Flow and pressure triggers

 

Pressure Limit/Alarm

 

Mode of Ventilation

 

I-Time (Adaptive or Set)

 

I:E ratio

 

FIO2

  Exhaled Minute Volume
  Peak Flow (Adaptive or Set)
 

Internal battery icon

 

Set PSV

   
 

Graphics and Loops

Pressure and Flow real time waveforms

 

Pressure-volume loops

 

Pressure-flow loops

 

Volume-flow loops

  RR (high/low)
   
 
Alarm Settings:

 

Minute Volume (high/low)

 

Pressure (high/low)

 

Apnea (0-120 seconds)

 

FIO2 (high/low)

 

Leak (0-90%)

 

Inverse I:E ratio

  Low Tidal Volume %
   
 
Non-Adjustable Alarms

 

Low O2 pressure

 

AC Disconnect

 

Low Battery/ Battery Empty

 

Over Temperature

 

Service Notice

 

Patient Disconnect

 

Check Sensor

 

Tube Disconnect

   
 
Electrical/Pneumatic Input-Output

Internal turbine

Provides compressed air up to 180 L/Min. demand flow. Battery operated to provide a gas source during transports or loss of power.

D/C power

Standard internal battery provides up to 2 hours of operation (depending on ventilatory load). There is a standard external battery coupler on back to add an external battery source.

 

Communication port to transfer ventilator information to

RS-232 (out)

another electronic device or video screen.

RS-232 (in)

Communication port to transfer software upgrades into the ventilator.

Keyboard input

To allow easy upgrades to internal software.

Remote alarm jack

To connect the ventilator to remote alarms or to nurse call systems.

   
 
Misc. Operation

Oxygen supply

The iVent201 operates with either high or low pressure oxygen sources.

NBC filter

The iVent201 was manufactured to operate in field (nuclear/ biological/chemical)situations where there may be biological agents or chemical gases.

  Display screens
  The iVent201 has three display screens designed for varying applicati
  Adaptive Flow TM
  Adaptive Flow allows the patient to receive the amount of flow they desire. Adaptive Flow performs 3 functions:
  For a non-breathing patient, Adaptive Flow will utilize the lowest possible peak flow to deliver a breath in the allotted inspiratory time. By delivering the breath at the lowest peak flow the inspiratory pressures for that breath are minimized thus reducing the risk of barotrauma.
  For a spontaneously breathing patient, Adaptive Flow detects and matches the patient ‘s natural inspiratory flow rate.
  For timed breaths interspersed with spontaneous breaths adaptive flow delivers the appropriate flow necessary to reach the target volume within the allotted time, while maintaining an I-time that results in an I:E of 1:2.
  Adaptive I-Time TM
 
This feature, which can be activated in volume mode, allows the patient to take charge of their inspiratory time while keeping their I:E ratio at 1:2. In this mode, if the patient's rate increases, the ventilator decreases I-Time in an attempt to keep the 1:2 ratio and conversely will increase the I-Time if the rate drops.
  The Rise Time is automatic and Adaptive I-Time is generally used in unison with Adaptive Flow. When combined the two features dramatically increase patient comfort by
  Reducing Air Hunger
  Decreasing Dyspnea
Þ Reducing PIP
Þ Pressure Limited Volume Ventilation
 
The iVent201 has the capability to limit the delivery pressure of a volume breath. This feature allows the user to set a pressure limit, the pressure a breath will not exceed. This ensures the pressures will remain low enough to protect the lung from barotrauma. If the target pressure is reached during the inspiratory phase, the ventilator will “hold” the breath at the set pressure until the I-Time is reached.
Þ Quick set-up
 
The iVent201 has pre-determined settings based on the patients' ideal body weight. This allows very quick application of the vent in emergency/non-clinician settings.
Þ Sound Investment
 
Healthcare providers can use one machine (and one circuit) for a broad range of patients from pediatric to adult with invasive and face mask ventilation and CPAP.
 
A portable ventilator with the advanced capabilities of a heavy-duty ventilator, the iVent201 is ideal in the ER, ICU, transport, EMS, long-term care/sub-acute, and home care.
Þ Apnea Backup Ventilation
  In case of apnea, the iVent201 will initiate ventilation based on an average of the previous twelve breaths. If apnea is detected prior to an average taken, the ventilator will use the IBW, which was set at start up.
  For instance, if the patient was in a volume mode, the patient will receive a Vt of 10 ml per selected kg, and the rate will vary based on the weight chosen.
Þ Internal PEEP
 
The iVent201 utilizes a mushroom valve located in the expiratory limb of the circuit to control exhalation and PEEP. A sensor line applies and maintains the clinician set pressure on the valve. This system is much more accurate and adds considerably less weight than the dial type valves located at the distal end of some ventilator circuits.
Þ Easy Exhale
 
Easy Exhale is a patient comfort feature found on the iVent201. This feature unloads all resistance from the expiratory valve at the beginning of exhalation. Once the baseline PEEP has been met, the PEEP is then reapplied. By exhaling against zero PEEP, the patient's expiratory work of breathing is greatly reduced and comfort dramatically increased.
Þ Software Upgradeability
 
The iVent201 is based on computer platform that allows it to be upgraded in the same manner as the software on a PC. Many other software driven ventilators utilize EPROM programs that are not upgradeable, and updates mean a complete program change out is needed.
 
With the iVent201 we just add on to existing software program which makes the upgrade fast, easy and able to be performed on site with very little down time.
Þ Ease of Use
 
The menu on the iVent201 is accessed by the click-turn-click rotational control that makes it very user friendly. The user is never more than one menu deep in the program. Most functions operate from a popup screen format.
 
The iVent201 has the ventilation modalities and capacity to handle 90% of all patients requiring ventilation. It is the first ventilator on the market designed to handle both face mask and invasive.
Þ Transportable Face-Mask Ventilation
 
Weighing 22lbs, the iVent201 with its self-contained turbine and internal battery is the only truly transportable ventilators capable of providing face mask ventilation.
   
 
Physical Features

User Interface

Single Rotational control, push/turn to access all data and menu information Color LCD that indicates all settings and actual parameters. Graphics and special menu functions are also presented for clinician use
Clinician chosen display interface: ICU/Monitoring/Home Care

Physical Design

Designed for easy cleaning and quick turn-around
Rugged build
Small, lightweight design allows for easy transport

   
 
Configuration Features

Quick set-up

The iVent201 has pre-determined settings based on the patients' ideal body weight. This allows very quick application of the vent in emergency/non-clinician settings

Circuit Compliance

Not necessary as all pressures, volumes and compensation flows are measured at the patients' wye

Pre-set Default

Used for typical setting for specific clinical applications

Patient Triggers

Configured to have both pressure and flow triggers as default. First trigger sensed initiates breath

   
 
Modes:

Assist Control, Volume

All modes of ventilation may be used

Assist Control, Pressure

with both pediatric and adult patients.

SIMV, Volume

This allows great versatility to meet

SIMV, Pressure

clinical demands

SIMV, Pressure

 

CPAP/PSV

 
Pressure Limited Volume  
Control  

Adaptive Bi-Level

 
   
 
Manual Controls:

Alarm Silence

Mutes the alarm for two minutes

100% O2

Pressing this key allows for 3 minutes of 100% O2 and two minutes of alarm silence during suction procedures

Manual Breath

Enables the operator to deliver a single breath. In the CPAP/PSV modes, where there isn't any defined machine breath, the delivered breath will be default volume for the specified patient weight

Clear

This key will minimize alarm pop-ups and mute the alarm for 30 seconds. This key also aborts the last operator action and returns to the previous position. When held for 2 seconds, all corrected alarm messages (displayed in green) are cleared from the screen and/or alarm silence is cancelled

   
 
Trends/Log Book

Patient Trends

There are 14 different parameters available to trend. Trended information is held for 72 hours on a first in, first out basis. This information can be browsed with a cursor for exact information at exact times.

Log Book

Parameter changes and alarms are logged for 300 events on

 

a first in, first out basis. The viewable log is erased once the unit is powered off.

   
 
Proximal Flow/Pressure/Volume Sensing

Dual Pressure Transducers

The combination of proximal and distal pressure sensors in the circuit wye allows for extremely accurate measurements of delivered and exhaled volumes. The iVent computer deciphers pressure changes into volume and flow.

   
 
Advanced Mechanics

Compliance

Updated breath to breath

Mean Airway Pressure

Updated breath to breath

Airway Resistance

Updated breath to breath

   
 
Monitored Parameters
 

Mandatory Vt

 

Set PEEP

 

Actual Vt

 

PIP with bar graph

 

% Leak

 

MAP

 

Mandatory RR

 

Resistance

 

Actual RR

 

Compliance

 

Flow and pressure triggers

 

Pressure Limit/Alarm

 

Mode of Ventilation

 

I-Time (Adaptive or Set)

 

I:E ratio

 

FIO2

 

Exhaled Minute Volume

 

Peak Flow (Adaptive or Set)

 

Internal battery icon

 

Set PSV

   
 

Graphics and Loops

Pressure and Flow real time waveforms

 

Pressure-volume loops

 

Pressure-flow loops

 

Volume-flow loops

 

RR (high/low)

   
 
Alarm Settings:

 

Minute Volume (high/low)

 

Pressure (high/low)

 

Apnea (0-120 seconds)

 

FIO2 (high/low)

 

Leak (0-90%)

 

Inverse I:E ratio

 

Low Tidal Volume %

 

Non-Adjustable Alarms

Low O2 pressure

 

AC Disconnect

 

Low Battery/ Battery Empty

 

Over Temperature

 

Service Notice

 

Patient Disconnect

 

Check Sensor

 

Tube Disconnect

   
 
Electrical/Pneumatic Input-Output

Internal turbine

 

Provides compressed air up to 180 L/Min. demand flow. Battery operated to provide a gas source during transports or loss of power.

D/C power

Standard internal battery provides up to 2 hours of operation (depending on ventilatory load). There is a standard external battery coupler on back to add an external battery source.
Communication port to transfer ventilator information to

RS-232 (out)

another electronic device or video screen.

RS-232 (in)

Communication port to transfer software upgrades into the ventilator.

Keyboard input

To allow easy upgrades to internal software.

Remote alarm jack

To connect the ventilator to remote alarms or to nurse call systems.

   
 
Misc. Operation

Oxygen supply

The iVent201 operates with either high or low pressure oxygen sources.

NBC filter

The iVent201 was manufactured to operate in field (nuclear/ biological/chemical)situations where there may be biological agents or chemical gases.

Display screens

The iVent201 has three display screens designed for varying applications.

Upgradeable

As new needs in ventilation occur (i.e. non-invasive ventilation) the iVent201 can be easily upgraded without having to purchase another platform.

Cost of Ownership

Yearly PM's include changing of the internal O2 fuel cell and the internal filters. Calibrations are done with an O2 source, 500 cc syringe, pressure manometer and a 2L test lung.
Biomedical training is available.
Extended warranties are available.

Rugged Exterior

Operates in difficult environments such as transport, ambulances and planes.

ons.
Upgradeable

As new needs in ventilation occur (i.e. non-invasive ventilation) the iVent201 can be easily upgraded without having to purchase another platform.

Cost of Ownership

Yearly PM's include changing of the internal O2 fuel cell and the internal filters. Calibrations are done with an O2 source, 500 cc syringe, pressure manometer and a 2L test lung.
Biomedical training is available.
Extended warranties are available.

Rugged Exterior

Operates in difficult environments such as transport, ambulances and planes.

 
Most of our product provides you with the excellent quality of ecg equipments like baby incubator, medical baby incubator. We need to work with our customers to understand their needs. We are also supplier of other important products like Laryngoscopes, Surgical disposable, Vaccine carrier, Orthopaedic implants etc. We are selling our products in Asia, United Kingdom, Jordan, Japan, Saudi Arabia and Philippines.
« Our Partner Sites »
» www.ademcoindia.com » www.laryngoscopes.net »

www.laryngoscope.org

» www.vaccinecarrier.net »

www.vaccinecarrier.org

»

www.vaccinecarrier.com

    » www.gayatrihouse.com    
Copyright © 2004. Ademco. All Rights Reserved. Website created by CFCS